CJYRX - AC108970050, 2-CHLOROCYCLOPENTANONE(SUPDAT)

  • MSDS: CJYRX
  • Manufacturer: FISHER SCIENTIFIC
  • Product Name: AC108970050, 2-CHLOROCYCLOPENTANONE(SUPDAT)
  • National Stock Number: -
Product Identification

Product ID:AC108970050, 2-CHLOROCYCLOPENTANONE(SUPDAT)
MSDS Date:09/02/1997
FSC:NIIN:Submitter:N EN
Status Code:A
MSDS Number: CJYRX

Responsible Party
FISHER SCIENTIFIC
ONE REAGENT LANE
FAIRLAWN, NJ 07410
US

Emergency Phone: 201-796-7100

Info Phone: 201-796-7100

Cage: 1B464

Contractor
FISHER SCIENTIFIC CO. CHEMICAL MFG DIV
FAIRLAWN, NJ 07410-2802 US

Telephone: 201-796-7100

Cage: 1B464

Ingredients

211-769-9)

CAS: 694-28-0

RTECS: GY4900000

Fraction By Weight: 97%

Hazards

Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYE: LACHRYMATOR. SKIN: NOT
AVAILABLE. INGESTION: NOT AVAILABLE. INHALATION: NOT AVAILABLE.
CHRONIC: NOT AVAILABLE. TARGET ORGANS: NONE.
Explanation of Carcinogenicity:CAS# 694-28-0: NOT LISTED BY ACGIH,
IARC, NIOSH, NTP, OR OSHA.
Effects of Overexposure:SEE HEALTH HAZARDS.

First Aid

First Aid:INGEST: CALL MD IMMEDIATELY . INHAL: REMOVE TO FRESH AIR.
SUPPORT BREATHING (GIVE OXYGEN/ARTIFICIAL RESPIRATION) . EYES:
IMMEDIATELY FLUSH EYES W/POTABLE WATER FOR AT LEAST 15 MINUTES, SEE
K ASSISTANCE FROM MD . SKIN: FLUSH W/COPIOUS AMOUNTS OF WATER. CALL
MD . NOTES TO PHYSICIAN: TREAT SYMPTOMATICALLY.

Fire Fighting

Flash Point:=77.C, 170.6F
Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT .

Accidental Release

Spill Release Procedures:GENERAL INFORMATION: USE PROPER PERSONAL
PROTECTIVE EQUIPMENT AS INDICATED IN EXPOSURE CONTROLS, PERSONAL
PROTECTION (SECTION 8). SPILL/LEAKS: NOT AVAILABLE.

Handling

Handling and Storage Precautions:REFRIGERATOR (APPROX 40C).
Other Precautions:NOT AVAILABLE.

Exposure Controls

Respiratory Protection:NIOSH APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
Supplemental Safety and Health
TRADE NAME/PART NO.: 97% (STABILIZED WITH 200 PPM H.Q.)

Chemical Properties

Boiling Pt:>72.C, 161.6F
B.P. Text:72-74C @ 12 MM HG
Spec Gravity:1.1850G/CM3
Solubility in Water:NOT AVAILABLE
Appearance and Odor:CLEAR PINK TO BROWN.

Stability

Stability Indicator/Materials to Avoid:YES

Disposal

Waste Disposal Methods:DISPOSE OF IN A MANNER CONSISTENT WITH FEDERAL,
STATE, AND LOCAL REGULATIONS. RCRA D-SERIES MAX CONC OF
CONTAMINANTS: NOT LISTED. RCRA D-SERIES CHRONIC TOX REFERENCE
LEVELS: NONE LISTED. RCRA F, P, & U SERIES: NONE LISTED.

Toxicology

Toxicological Information:CAS#694-28-0: GY4900000. LD50/LC50: NOT
AVAILABLE. CARCINOGENCITY: CAS# 694-28-0: NOT LISTED BY ACGIH,
IARC, NIOSH, NTP, OR OSHA. EPIDEMIOLOGY, TERATOGENICITY,
REPRODUCTIVE EFFECTS, NEUROTOXICITY, MUT AGENICITY AND OTHER
STUDIES: NO DATA AVAILABLE.

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ecology

Ecological:ECOTOXICITY, ENVIRONMENTAL FATE, PHYSICAL/CHEMICAL AND
OTHER: NOT AVAILABLE.

Transport

Transport Information:US DOT: DOT REGULATED-SMALL QTY PROVISIONS APPLY
(SEE 49CFR173.4). IATA: NOT REGULATED AS HAZARDOUS MATERIAL.
RID/ADR: NOT REGULATED AS HAZARDOUS MATERIAL. IMO: NOT REGULATED AS
HAZARDOUS MATERIAL. CA NADA TDG: POISONOUS LIQUID NOS
(2-CHLOROCYCLOPENTANONE). HAZARD CLASS: HAZ CLASS: 6.1(9.2). UN
NUMBER: CANADA TDG: UN2810. PACKING GROUP:: III.

Regulatory

SARA Title III Information:SECTION 302(RQ): NONE OF CHEMS IN MATL HAVE
RQ. SECTION 302(TPQ): NONE OF CHEMS IN PROD HAVE TPQ. SECTION 313:
NO CHEMS ARE REPORTABLE UNDER SECTION 313. CLEAN AIR ACT: MATL DOES
NOT CNTN HAZ AIR POLL UTANTS. THIS MATL DOES NOT CNTN ANY CLASS 1
OZONE DEPLETORS. MATL DOES NOT CNTN ANY CLASS 2 OZONE DEPLETORS.
CLEAN WATER ACT: NONE OF CHEMS IN PROD ARE LISTED AS HAZ SUBSTANCES
UNDER CWA. NONE OF CHEM S IN PROD ARE LISTED AS PRIORITY POLLUTANTS
UNDER CWA. NONE OF CHEMS IN PROD ARE LISTED AS TOXIC POLLUTANTS
UNDER CWA. OSHA: NONE OF CHEMS IN PROD ARE LISTED TOXIC POLLUTANTS
UNDER CWA.
Federal Regulatory Information:TSCA CAS# 694-28-0 IS LISTED ON THE TSCA
INVENTORY. HEALTH & SAFETY REPORTING LIST: NONE OF CHEMICALS ARE ON
HEALTH & SAFETY REPORTING LIST. CHEMICAL TEST RULES: NONE OF THE
CHEMICALS IN THIS PRODUCT ARE UNDER A CHEMICAL TEST RULE. SECTION
12B: NONE OF CHEMICALS IN THIS PRODUCT ARE UNDER A CHEMICAL TEST
RULE. SECTION 12B: NONE OF CHEMS ARE LISTED UNDER TSCA SECTION 12B.
TSCA SIGNIFICANT NEW USE RU LE: NONE OF CHEMICALS IN THIS MATERIAL
HAVE A SNUR UNDER TSCA.
State Regulatory Information:CAS# 694-28-0 IS NOT PRESENT ON STATE
LISTS FROM CA/PA, MN, MA, FL, OR NJ. CALIFORNIA NO SIGNIFICANT RISK
LEVEL: NONE OF CHEMICALS IN THIS PRODUCT ARE LISTED.